In this paper we used Na2CO3-impregnated silica as reactive substrate for the determination of atmospheric NOx(NO+NO2) by using a passive sampling device, with radial symmetry, which is unprecedented. We conducted laboratory and field tests at an urban setting, with co-located passive samplers and continuous measurements of NOxby a chemiluminescence detector, used as reference. The performance of the carbonate-based sorbent for the NOxsampler was evaluated in two different time frames (autumn 2016 and winter 2017), characterised by different environmental conditions. The comparison of the NOxconcentration levels measured by passive sampling, using Na2CO3as NOxsorbent, showed a close relationship with those obtained by the chemiluminescence analyzer. Validation experiments in the laboratory and in the field are reported together with the calculation of the diffusion-sampling rate of the samplers.
Development of a new radial passive sampling device for atmospheric NOxdetermination / Motta, Oriana; Cucciniello, Raffaele; La Femina, Rosa; Pironti, Concetta; Proto, Antonio. - In: TALANTA. - ISSN 0039-9140. - 190:(2018), pp. 199-203. [10.1016/j.talanta.2018.07.088]
Development of a new radial passive sampling device for atmospheric NOxdetermination
Raffaele Cucciniello;Concetta Pironti;Antonio Proto
2018
Abstract
In this paper we used Na2CO3-impregnated silica as reactive substrate for the determination of atmospheric NOx(NO+NO2) by using a passive sampling device, with radial symmetry, which is unprecedented. We conducted laboratory and field tests at an urban setting, with co-located passive samplers and continuous measurements of NOxby a chemiluminescence detector, used as reference. The performance of the carbonate-based sorbent for the NOxsampler was evaluated in two different time frames (autumn 2016 and winter 2017), characterised by different environmental conditions. The comparison of the NOxconcentration levels measured by passive sampling, using Na2CO3as NOxsorbent, showed a close relationship with those obtained by the chemiluminescence analyzer. Validation experiments in the laboratory and in the field are reported together with the calculation of the diffusion-sampling rate of the samplers.File | Dimensione | Formato | |
---|---|---|---|
Talanta 190 (2018)_passive NOx.pdf
non disponibili
Licenza:
Non specificato
Dimensione
291.51 kB
Formato
Adobe PDF
|
291.51 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.