The existing Reinforced Concrete (RC) buildings stock is often characterized by a significant seismic vulnerability, due to the absence of capacity design principles, even in regions with high seismic hazard, such as Italy. Approximately 67% of existing RC buildings in Italy have been designed without considering seismic actions (GLD), resulting in very low transverse reinforcement amount in beams and, particularly, in columns. Additionally, beam-column joints typically totally lack stirrups. Consequently, shear failures under seismic actions are very likely for this pre-code building typology, often limiting their seismic capacity. However, the assessment of shear failures in beams/columns or joints varies significantly from code to code worldwide. The main goal of this work is to quantify the impact of different code-based brittle capacity models on the seismic capacity assessment and retrofit, focusing on GLD Italian pre-1970 RC buildings. This comparative analysis is carried out by first considering three current codes, emphasizing their, even significant, differences: European (EN 1998-3-1. 2005), Italian (D.M. 2018), and American (ASCE SEI/41 2017) standards. Then, shear capacity models prescribed by the current drafts of the next generation of Eurocodes are implemented and compared to the current models. The assessment includes: (i) a parametric comparison among models; (ii) the evaluation of case-study buildings capacity in their as-built condition and after shear strengthening interventions. The latter is performed on 3D “bare” models, due to the lack of practical guidance in most codes on modelling masonry infills.

Code-based brittle capacity models for seismic assessment of pre-code RC buildings: comparison and consequences on retrofit / Scala, S. A.; De Risi, M. T.; Verderame, G. M.. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - (2024). [10.1007/s10518-024-02016-6]

Code-based brittle capacity models for seismic assessment of pre-code RC buildings: comparison and consequences on retrofit

Scala S. A.;De Risi M. T.
;
Verderame G. M.
2024

Abstract

The existing Reinforced Concrete (RC) buildings stock is often characterized by a significant seismic vulnerability, due to the absence of capacity design principles, even in regions with high seismic hazard, such as Italy. Approximately 67% of existing RC buildings in Italy have been designed without considering seismic actions (GLD), resulting in very low transverse reinforcement amount in beams and, particularly, in columns. Additionally, beam-column joints typically totally lack stirrups. Consequently, shear failures under seismic actions are very likely for this pre-code building typology, often limiting their seismic capacity. However, the assessment of shear failures in beams/columns or joints varies significantly from code to code worldwide. The main goal of this work is to quantify the impact of different code-based brittle capacity models on the seismic capacity assessment and retrofit, focusing on GLD Italian pre-1970 RC buildings. This comparative analysis is carried out by first considering three current codes, emphasizing their, even significant, differences: European (EN 1998-3-1. 2005), Italian (D.M. 2018), and American (ASCE SEI/41 2017) standards. Then, shear capacity models prescribed by the current drafts of the next generation of Eurocodes are implemented and compared to the current models. The assessment includes: (i) a parametric comparison among models; (ii) the evaluation of case-study buildings capacity in their as-built condition and after shear strengthening interventions. The latter is performed on 3D “bare” models, due to the lack of practical guidance in most codes on modelling masonry infills.
2024
Code-based brittle capacity models for seismic assessment of pre-code RC buildings: comparison and consequences on retrofit / Scala, S. A.; De Risi, M. T.; Verderame, G. M.. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - (2024). [10.1007/s10518-024-02016-6]
File in questo prodotto:
File Dimensione Formato  
2024_Scala_DeRIsi_Verderame.pdf

accesso aperto

Licenza: Creative commons
Dimensione 3.52 MB
Formato Adobe PDF
3.52 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/980167
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact