The paper presents analytical formulas for computation in the time domain of electromagnetic (EM) fields generated by tortuous cloud-to-cloud (CC) lightning channels over a perfectly conducting ground. For the first time, the study was not limited to a horizontal lightning path but was extended to take into account the natural, tortuous geometry of the lightning channel. After the calculation of the step response, a convolution integration was applied for the computation of the fields generated by an arbitrary current source. The produced electric and magnetic fields were then compared with the fields generated by a horizontal channel. The method can be of primary importance to evaluating the hazards for electric and electronic systems of flying aircraft, estimating the voltages induced on overhead transmission lines by CC lightning, and, in general, evaluating the induced effects on sensitive electric and electronic components. Moreover, it may represent a simple, robust, and time-saving tool for estimating important physical parameters that characterize lightning phenomena.

Computation of Electric and Magnetic Fields Generated by Cloud-to-Cloud Lightning Channels / Petrarca, C.; Balato, M.; Verolino, L.; Andreotti, A.; Assante, D.. - In: ENERGIES. - ISSN 1996-1073. - 16:11(2023), p. 4524. [10.3390/en16114524]

Computation of Electric and Magnetic Fields Generated by Cloud-to-Cloud Lightning Channels

Petrarca C.;Balato M.;Verolino L.;Andreotti A.;
2023

Abstract

The paper presents analytical formulas for computation in the time domain of electromagnetic (EM) fields generated by tortuous cloud-to-cloud (CC) lightning channels over a perfectly conducting ground. For the first time, the study was not limited to a horizontal lightning path but was extended to take into account the natural, tortuous geometry of the lightning channel. After the calculation of the step response, a convolution integration was applied for the computation of the fields generated by an arbitrary current source. The produced electric and magnetic fields were then compared with the fields generated by a horizontal channel. The method can be of primary importance to evaluating the hazards for electric and electronic systems of flying aircraft, estimating the voltages induced on overhead transmission lines by CC lightning, and, in general, evaluating the induced effects on sensitive electric and electronic components. Moreover, it may represent a simple, robust, and time-saving tool for estimating important physical parameters that characterize lightning phenomena.
2023
Computation of Electric and Magnetic Fields Generated by Cloud-to-Cloud Lightning Channels / Petrarca, C.; Balato, M.; Verolino, L.; Andreotti, A.; Assante, D.. - In: ENERGIES. - ISSN 1996-1073. - 16:11(2023), p. 4524. [10.3390/en16114524]
File in questo prodotto:
File Dimensione Formato  
energies-16-04524 - Published paper.pdf

solo utenti autorizzati

Licenza: Dominio pubblico
Dimensione 1.17 MB
Formato Adobe PDF
1.17 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/985811
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact