Objectives. Patent hemostasis (PH) is essential for preventing radial artery occlusion (RAO) after trans-radial procedures; however, it remains unclear how it should be obtained. The aim of this multicenter randomized study was to evaluate whether the use of an adjustable device (AD), inflated with a pre-determined amount of air (AoA), was more effective than a non-adjustable device (non-AD) for achieving PH, thereby reducing the incidence of RAO. Methods. We enrolled a total of 480 patients undergoing transradial procedure at 3 Italian institutions. Before the procedure, a modified Reverse Barbeau Test (mRBT) was performed in all patients to evaluate the AoA to be eventually inflated in the AD. After the procedure, patients were randomized into 2 groups: (1) AD Group, using TR-Band (Terumo) inflated with the pre-determined AoA; and 2) non-AD Group, using RadiStop (Abbott). An RBT was performed during compression to demonstrate the achievement of PH, as well as 24 hours later to evaluate the occurrence of RAO. Results. PH was more often obtained in the AD Group compared with the non-AD Group (90% vs 64%, respectively, P < .001), with no difference in terms of bleedings. RAO occurred more often in the non-AD Group compared with the AD Group (10% vs 3%, respectively, P < .001). Of note, mRBT was effective at guiding AD inflation and identifying high-risk patients in whom PH was more difficult to obtain. Conclusions. The use of AD, filled with a predetermined AoA, allowed PH significantly more often compared with non-AD, providing a significantly reduced incidence of RAO.

A Comparison Between Radial Artery Compression Devices for Patent Hemostasis After Transradial Percutaneous Interventions / Di Serafino, L.; Turturo, M.; Larosa, C.; Scalamogna, M.; Cirillo, P.; Angelilli, V. A.; Lanzone, S.; Bartolomucci, F.; Granata, R.; Saverio Rea, F.; Piccolo, R.; Franzone, A.; Gargiulo, G.; Spaccarotella, C. A. M.; Stabile, E.; Esposito, Giovanni. - In: JOURNAL OF INVASIVE CARDIOLOGY. - ISSN 1042-3931. - 36:5(2024). [10.25270/jic/23.00302]

A Comparison Between Radial Artery Compression Devices for Patent Hemostasis After Transradial Percutaneous Interventions

Di Serafino L.
Conceptualization
;
Turturo M.
Membro del Collaboration Group
;
Scalamogna M.
Investigation
;
Cirillo P.
Investigation
;
Piccolo R.
Membro del Collaboration Group
;
Franzone A.
Membro del Collaboration Group
;
Gargiulo G.
Membro del Collaboration Group
;
Spaccarotella C. A. M.
Membro del Collaboration Group
;
Stabile E.
Membro del Collaboration Group
;
Esposito Giovanni
2024

Abstract

Objectives. Patent hemostasis (PH) is essential for preventing radial artery occlusion (RAO) after trans-radial procedures; however, it remains unclear how it should be obtained. The aim of this multicenter randomized study was to evaluate whether the use of an adjustable device (AD), inflated with a pre-determined amount of air (AoA), was more effective than a non-adjustable device (non-AD) for achieving PH, thereby reducing the incidence of RAO. Methods. We enrolled a total of 480 patients undergoing transradial procedure at 3 Italian institutions. Before the procedure, a modified Reverse Barbeau Test (mRBT) was performed in all patients to evaluate the AoA to be eventually inflated in the AD. After the procedure, patients were randomized into 2 groups: (1) AD Group, using TR-Band (Terumo) inflated with the pre-determined AoA; and 2) non-AD Group, using RadiStop (Abbott). An RBT was performed during compression to demonstrate the achievement of PH, as well as 24 hours later to evaluate the occurrence of RAO. Results. PH was more often obtained in the AD Group compared with the non-AD Group (90% vs 64%, respectively, P < .001), with no difference in terms of bleedings. RAO occurred more often in the non-AD Group compared with the AD Group (10% vs 3%, respectively, P < .001). Of note, mRBT was effective at guiding AD inflation and identifying high-risk patients in whom PH was more difficult to obtain. Conclusions. The use of AD, filled with a predetermined AoA, allowed PH significantly more often compared with non-AD, providing a significantly reduced incidence of RAO.
2024
A Comparison Between Radial Artery Compression Devices for Patent Hemostasis After Transradial Percutaneous Interventions / Di Serafino, L.; Turturo, M.; Larosa, C.; Scalamogna, M.; Cirillo, P.; Angelilli, V. A.; Lanzone, S.; Bartolomucci, F.; Granata, R.; Saverio Rea, F.; Piccolo, R.; Franzone, A.; Gargiulo, G.; Spaccarotella, C. A. M.; Stabile, E.; Esposito, Giovanni. - In: JOURNAL OF INVASIVE CARDIOLOGY. - ISSN 1042-3931. - 36:5(2024). [10.25270/jic/23.00302]
File in questo prodotto:
File Dimensione Formato  
A Comparison Between Radial Artery Compression Devices for Patent Hemostasis After Transradial Percutaneous Interventions.pdf

solo utenti autorizzati

Licenza: Dominio pubblico
Dimensione 164.12 kB
Formato Adobe PDF
164.12 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/988540
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact