A bioimpedance transducer is proposed for noninvasive monitoring of insulin bioavailability after subcutaneous injection. The insulin bioavailability is assessed indirectly by measuring the local impedance variation due to the drug disappearance from the injection volume. The instrument allows to manage the extreme variability in insulin response by patients with diabetes due to skin conditions and/or alterations such as lipodystrophy. In this way, the transducer can also be considered as a key component for new generation of artificial pancreas. The instrument achieves the state-of-the-art accuracy and uncertainty. Intraindividual reproducibility also improved with respect to previous studies. Moreover, the feasibility of an absorption measurement is proven. After presenting the concept design and the prototype, the metrological characterization during: 1) laboratory (on passive electrical components); 2) in vitro (on eggplants); and 3) in vivo (on a human subject) experiments is reported. In laboratory tests, typical percentage deterministic errors of 1% on magnitude and phase were obtained. The mean 1- σ repeatability of 0.05% was obtained for both impedance magnitude and phase. The in vitro tests were aimed to improve the reproducibility by comparing the electrical behavior of insulin and vehicle in eggplants. During in vivo tests, a decrease in percentage 1- σ intraindividual reproducibility was reported with respect to the state-of-the-art (from more than 200% to 36%), as the impedance magnitude is concerned. In a clinical application framework, an accuracy of 9 μ l was obtained by means of a second-order polynomial model. The uncertainty was 4.2 μ l , well below the typical volume of one insulin unit (10.0 μ l).

A Reproducible Bioimpedance Transducer for Insulin Noninvasive Measurement / Arpaia, P.; Mancino, F.; Moccaldi, N.. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - 72:(2023), pp. 1-11. [10.1109/TIM.2023.3264037]

A Reproducible Bioimpedance Transducer for Insulin Noninvasive Measurement

Arpaia P.;Mancino F.;Moccaldi N.
2023

Abstract

A bioimpedance transducer is proposed for noninvasive monitoring of insulin bioavailability after subcutaneous injection. The insulin bioavailability is assessed indirectly by measuring the local impedance variation due to the drug disappearance from the injection volume. The instrument allows to manage the extreme variability in insulin response by patients with diabetes due to skin conditions and/or alterations such as lipodystrophy. In this way, the transducer can also be considered as a key component for new generation of artificial pancreas. The instrument achieves the state-of-the-art accuracy and uncertainty. Intraindividual reproducibility also improved with respect to previous studies. Moreover, the feasibility of an absorption measurement is proven. After presenting the concept design and the prototype, the metrological characterization during: 1) laboratory (on passive electrical components); 2) in vitro (on eggplants); and 3) in vivo (on a human subject) experiments is reported. In laboratory tests, typical percentage deterministic errors of 1% on magnitude and phase were obtained. The mean 1- σ repeatability of 0.05% was obtained for both impedance magnitude and phase. The in vitro tests were aimed to improve the reproducibility by comparing the electrical behavior of insulin and vehicle in eggplants. During in vivo tests, a decrease in percentage 1- σ intraindividual reproducibility was reported with respect to the state-of-the-art (from more than 200% to 36%), as the impedance magnitude is concerned. In a clinical application framework, an accuracy of 9 μ l was obtained by means of a second-order polynomial model. The uncertainty was 4.2 μ l , well below the typical volume of one insulin unit (10.0 μ l).
2023
A Reproducible Bioimpedance Transducer for Insulin Noninvasive Measurement / Arpaia, P.; Mancino, F.; Moccaldi, N.. - In: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT. - ISSN 0018-9456. - 72:(2023), pp. 1-11. [10.1109/TIM.2023.3264037]
File in questo prodotto:
File Dimensione Formato  
A_Reproducible_Bioimpedance_Transducer_for_Insulin_Noninvasive_Measurement.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Dominio pubblico
Dimensione 7.13 MB
Formato Adobe PDF
7.13 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/993289
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact