: Thrombin overexpression in serum serves as a critical biomarker and is implicated in several diseases associated with significant morbidity and mortality. Existing techniques for thrombin detection are time-consuming and require sophisticated equipment and extensive sample preparation procedures, which further delay the detection and increase the cost of the procedure. Early and accessible diagnosis at the point of care, especially in limited-resource countries, represents the first step of clinical interventions. To overcome these limitations, we have proposed an innovative, sustainable paper-based electrochemical detection platform for thrombin. In this work, a sustainable paper-based aptasensor was rationally designed, characterized, evaluated against conventional gold standard plastic-based substrates, and applied to human serum, yielding a detection limit of ~ 60 pM. The present method provides an efficient and user-friendly way for the detection of thrombin and potentially leading to better management and treatment outcomes for patients.

Cost-effective, user-friendly detection and preconcentration of thrombin on a sustainable paper-based electrochemical platform / Raucci, Ada; Sorrentino, Giuseppina; Singh, Sima; Borbone, Nicola; Oliviero, Giorgia; Piccialli, Gennaro; Terracciano, Monica; Cinti, Stefano. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - 417:(2025), pp. 1863-1872. [10.1007/s00216-025-05764-9]

Cost-effective, user-friendly detection and preconcentration of thrombin on a sustainable paper-based electrochemical platform

Raucci, Ada
Primo
;
Sorrentino, Giuseppina;Singh, Sima;Borbone, Nicola;Oliviero, Giorgia;Piccialli, Gennaro;Terracciano, Monica
;
Cinti, Stefano
2025

Abstract

: Thrombin overexpression in serum serves as a critical biomarker and is implicated in several diseases associated with significant morbidity and mortality. Existing techniques for thrombin detection are time-consuming and require sophisticated equipment and extensive sample preparation procedures, which further delay the detection and increase the cost of the procedure. Early and accessible diagnosis at the point of care, especially in limited-resource countries, represents the first step of clinical interventions. To overcome these limitations, we have proposed an innovative, sustainable paper-based electrochemical detection platform for thrombin. In this work, a sustainable paper-based aptasensor was rationally designed, characterized, evaluated against conventional gold standard plastic-based substrates, and applied to human serum, yielding a detection limit of ~ 60 pM. The present method provides an efficient and user-friendly way for the detection of thrombin and potentially leading to better management and treatment outcomes for patients.
2025
Cost-effective, user-friendly detection and preconcentration of thrombin on a sustainable paper-based electrochemical platform / Raucci, Ada; Sorrentino, Giuseppina; Singh, Sima; Borbone, Nicola; Oliviero, Giorgia; Piccialli, Gennaro; Terracciano, Monica; Cinti, Stefano. - In: ANALYTICAL AND BIOANALYTICAL CHEMISTRY. - ISSN 1618-2642. - 417:(2025), pp. 1863-1872. [10.1007/s00216-025-05764-9]
File in questo prodotto:
File Dimensione Formato  
s00216-025-05764-9.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 2.06 MB
Formato Adobe PDF
2.06 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/995236
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact