In this electrophoretic procedure for measuring isoenzymes of gamma-glutamyltransferase, patterns obtained are highly reproducible and the analytical imprecision (CV) ranges from 1.10% to 6.17%. A cellulose acetate support is used, at 220 V for 40 min. Sharply resolved isoenzyme bands were made visible by fluorescence scattered light, formed by use of a coumarin derivative as donor substrate. Two bands were observed for sera from normal subjects; four bands were variably present in sera from patients with different hepatobiliary diseases. Detection of the latter was satisfactory, down to a total activity in serum of 8-10 U/L. Three of the pathological bands were associated with low- and (or) very-low-density lipoproteins, whereas a major fraction of one of the normal bands in cirrhotic sera precipitated with high-density lipoprotein. The bands in normal sera, and one of the abnormal bands, did not.

Improved procedure for measuring gamma-glutamyltrasnferase isoenzyme in serum / Sacchetti, L; Castaldo, Giuseppe; Fortunato, G; Salvatore, F.. - In: CLINICAL CHEMISTRY. - ISSN 1056-599X. - 34:2(1988), pp. 419-422.

Improved procedure for measuring gamma-glutamyltrasnferase isoenzyme in serum.

CASTALDO, GIUSEPPE;FORTUNATO G;SALVATORE F.
1988

Abstract

In this electrophoretic procedure for measuring isoenzymes of gamma-glutamyltransferase, patterns obtained are highly reproducible and the analytical imprecision (CV) ranges from 1.10% to 6.17%. A cellulose acetate support is used, at 220 V for 40 min. Sharply resolved isoenzyme bands were made visible by fluorescence scattered light, formed by use of a coumarin derivative as donor substrate. Two bands were observed for sera from normal subjects; four bands were variably present in sera from patients with different hepatobiliary diseases. Detection of the latter was satisfactory, down to a total activity in serum of 8-10 U/L. Three of the pathological bands were associated with low- and (or) very-low-density lipoproteins, whereas a major fraction of one of the normal bands in cirrhotic sera precipitated with high-density lipoprotein. The bands in normal sera, and one of the abnormal bands, did not.
1988
Improved procedure for measuring gamma-glutamyltrasnferase isoenzyme in serum / Sacchetti, L; Castaldo, Giuseppe; Fortunato, G; Salvatore, F.. - In: CLINICAL CHEMISTRY. - ISSN 1056-599X. - 34:2(1988), pp. 419-422.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/137123
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 18
social impact