On 6th April 2009 an earthquake of magnitude M (w) = 6.3 occurred in the Abruzzo region; the epicentre was very close to the city of L'Aquila (about 6 km away). The event produced casualties and damage to buildings, lifelines and other infrastructures. An analysis of the main damage that reinforced concrete (RC) structures showed after the event is presented in this study. In order to isolate the main causes of structural and non-structural damage, the seismological characteristics of the event are examined, followed by an analysis of the existing RC building stock in the area. The latter issue came under scrutiny after the release of official data about structural types and times of construction, combined with a detailed review of the most important seismic codes in force in the last 100 years in Italy. Comparison of the current design provisions of the Italian and European codes with previous standards allows the main weaknesses of the existing building stock to be determined. Damage to structural and non-structural elements is finally analyzed thanks to photographic material collected in the first week after the event; the main causes of damage are then inferred.

6th April 2009 L’Aquila earthquake, Italy: Reinforced concrete building performance / Ricci, Paolo; De Luca, F.; Verderame, GERARDO MARIO. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - 9:1(2011), pp. 285-305. [10.1007/s10518-010-9204-8]

6th April 2009 L’Aquila earthquake, Italy: Reinforced concrete building performance

RICCI, PAOLO;VERDERAME, GERARDO MARIO
2011

Abstract

On 6th April 2009 an earthquake of magnitude M (w) = 6.3 occurred in the Abruzzo region; the epicentre was very close to the city of L'Aquila (about 6 km away). The event produced casualties and damage to buildings, lifelines and other infrastructures. An analysis of the main damage that reinforced concrete (RC) structures showed after the event is presented in this study. In order to isolate the main causes of structural and non-structural damage, the seismological characteristics of the event are examined, followed by an analysis of the existing RC building stock in the area. The latter issue came under scrutiny after the release of official data about structural types and times of construction, combined with a detailed review of the most important seismic codes in force in the last 100 years in Italy. Comparison of the current design provisions of the Italian and European codes with previous standards allows the main weaknesses of the existing building stock to be determined. Damage to structural and non-structural elements is finally analyzed thanks to photographic material collected in the first week after the event; the main causes of damage are then inferred.
2011
6th April 2009 L’Aquila earthquake, Italy: Reinforced concrete building performance / Ricci, Paolo; De Luca, F.; Verderame, GERARDO MARIO. - In: BULLETIN OF EARTHQUAKE ENGINEERING. - ISSN 1570-761X. - 9:1(2011), pp. 285-305. [10.1007/s10518-010-9204-8]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/418230
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 271
  • ???jsp.display-item.citation.isi??? 237
social impact