A number of fiber reinforced plastic (FRP) rods can be used as fully bonded tendons in pretensioned prestressed concrete (PC) members. In this research Project, the development and flexural bond lengths of braided epoxy-impregnated FRP tendons made of aramid fiber were examined. Development length was determined by performing a three-Point flexural test (static monotonic load), and flexural bond length was computed on the basis of previous knowledge of transfer length. Variables included tendon material/manufacturing (flexible FRP rod. rigid sand-adhered FRP rod, and seven-wire steel strand), tendon size and number, initial prestress force, and presence or absence of shear reinforcement. It is found that development length of braided aramid FRP tendons is relatively short Recommended values Of development length expressed in terms of nominal tendon diameters are given.

Pretensioned Prestressed Concrete Members With Bonded Fiber Reinforced Plastic Tendons - Development and Flexural Bond Lengths (static) / Nanni, Antonio; M., Tanigaki. - In: ACI STRUCTURAL JOURNAL. - ISSN 0889-3241. - STAMPA. - 89:(1992), pp. 433-441.

Pretensioned Prestressed Concrete Members With Bonded Fiber Reinforced Plastic Tendons - Development and Flexural Bond Lengths (static)

NANNI, ANTONIO;
1992

Abstract

A number of fiber reinforced plastic (FRP) rods can be used as fully bonded tendons in pretensioned prestressed concrete (PC) members. In this research Project, the development and flexural bond lengths of braided epoxy-impregnated FRP tendons made of aramid fiber were examined. Development length was determined by performing a three-Point flexural test (static monotonic load), and flexural bond length was computed on the basis of previous knowledge of transfer length. Variables included tendon material/manufacturing (flexible FRP rod. rigid sand-adhered FRP rod, and seven-wire steel strand), tendon size and number, initial prestress force, and presence or absence of shear reinforcement. It is found that development length of braided aramid FRP tendons is relatively short Recommended values Of development length expressed in terms of nominal tendon diameters are given.
1992
Pretensioned Prestressed Concrete Members With Bonded Fiber Reinforced Plastic Tendons - Development and Flexural Bond Lengths (static) / Nanni, Antonio; M., Tanigaki. - In: ACI STRUCTURAL JOURNAL. - ISSN 0889-3241. - STAMPA. - 89:(1992), pp. 433-441.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/470335
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 26
social impact