The computer-based method allows the computerized planning of a surgical implantology procedure, using computed tomography (CT) of the maxillary bones and prosthesis. This procedure, however, is not error-free, unless the operator has been well trained and strictly follows the protocol. A 70-year-old woman whom was edentulous asked for a lower jaw implant-supported prosthesis. A computer-guided surgery was planned with an immediate loading according to the NobelGuide technique. However, prior to surgery, new dentures were constructed to adjust the vertical dimension. An interim screwed metal-resin prosthesis was delivered just after the surgery; however, after only two weeks, it was removed because of a complication. Finally, a screwed implant bridge was delivered. The computer guided surgery is a useful procedure when based on an accurate 3D CT-based image data and an implant planning software which minimizes errors.

Computer guided implantology accuracy and complications / Bruno, Vincenzo; Badino, Mauro; Riccitiello, Francesco; Spagnuolo, Gianrico; Amato, Massimo. - In: CASE REPORTS IN DENTISTRY. - ISSN 2090-6447. - 2013:(2013), pp. 701421-701426. [10.1155/2013/701421]

Computer guided implantology accuracy and complications

RICCITIELLO, FRANCESCO;SPAGNUOLO, GIANRICO;
2013

Abstract

The computer-based method allows the computerized planning of a surgical implantology procedure, using computed tomography (CT) of the maxillary bones and prosthesis. This procedure, however, is not error-free, unless the operator has been well trained and strictly follows the protocol. A 70-year-old woman whom was edentulous asked for a lower jaw implant-supported prosthesis. A computer-guided surgery was planned with an immediate loading according to the NobelGuide technique. However, prior to surgery, new dentures were constructed to adjust the vertical dimension. An interim screwed metal-resin prosthesis was delivered just after the surgery; however, after only two weeks, it was removed because of a complication. Finally, a screwed implant bridge was delivered. The computer guided surgery is a useful procedure when based on an accurate 3D CT-based image data and an implant planning software which minimizes errors.
2013
Computer guided implantology accuracy and complications / Bruno, Vincenzo; Badino, Mauro; Riccitiello, Francesco; Spagnuolo, Gianrico; Amato, Massimo. - In: CASE REPORTS IN DENTISTRY. - ISSN 2090-6447. - 2013:(2013), pp. 701421-701426. [10.1155/2013/701421]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/662826
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 1
social impact