Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
The PEANUT experiment was designed to study the NuMi neutrino beam at Fermilab. The detector uses a hybrid technique, being made of nuclear emulsions and scintillator trackers. Emulsion films act as a micrometric tracking device and are interleaved with lead plates used as passive material. The detector is designed to precisely reconstruct the topology of neutrino interactions and hence to measure the different contributions to the cross section. We present here the full reconstruction and analysis of 147 neutrino interactions and the measurement of the quasi-elastic, resonance and deep-inelastic contributions to the total charged current cross section at the energies of the NuMi neutrino beam. This technique could be applied for beam monitoring in future neutrino facilities, and this paper shows its proof-of-principle.
Measurement of low-energy neutrino cross-sections with the PEANUT experiment / Aoki, S; Ariga, A; Arrabito, L; Autiero, D; Besnier, M; Bozza, C; Buontempo, S; Carrara, E; Consiglio, L; Cozzi, M; D'Ambrosio, N; De Lellis, G; Déclais, Y; De Serio, M; DI CAPUA, Francesco; Di Crescenzo, A; Di Ferdinando, D; Di Marco, N; Duchesneau, D; Ereditato, A; Esposito, L. S; Fukuda, T; Giacomelli, G; Giorgini, M; Grella, G; Hamada, K; Ieva, M; Juget, F; Kitagawa, N; Knuesel, J; Kodama, K; Komatsu, M; Kose, U; Kreslo, I; Laktineh, I; Longhin, A; Lundberg, B; Lutter, G; Mandrioli, G; Marotta, A; Meisel, F; Migliozzi, P; Morishima, K; Muciaccia, M. T; Naganawa, N; Nakamura, M; Nakano, T; Niwa, K; Nonoyama, Y; Paolone, V; Pastore, A; Patrizii, L; Pistillo, C; Pozzato, M; Pupilli, F; Rameika, R; Rescigno, R; Rosa, G; Russo, A; Sato, O; Scotto Lavina, L; Simone, S; Sioli, M; Sirignano, C; Sirri, G; Strolin, P; Tenti, M; Tioukov, V; Yoshida, J; Yoshioka, T.. - In: NEW JOURNAL OF PHYSICS. - ISSN 1367-2630. - 12:11(2010), p. 113028. [10.1088/1367-2630/12/11/113028]
Measurement of low-energy neutrino cross-sections with the PEANUT experiment
The PEANUT experiment was designed to study the NuMi neutrino beam at Fermilab. The detector uses a hybrid technique, being made of nuclear emulsions and scintillator trackers. Emulsion films act as a micrometric tracking device and are interleaved with lead plates used as passive material. The detector is designed to precisely reconstruct the topology of neutrino interactions and hence to measure the different contributions to the cross section. We present here the full reconstruction and analysis of 147 neutrino interactions and the measurement of the quasi-elastic, resonance and deep-inelastic contributions to the total charged current cross section at the energies of the NuMi neutrino beam. This technique could be applied for beam monitoring in future neutrino facilities, and this paper shows its proof-of-principle.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/667795
Citazioni
ND
ND
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.