In the uncertainty assessment of magnetic flux measurements in axially symmetric magnets by the translating coil method, the Guide to the Uncertainty in Measurement and its supplement cannot be applied: the voltage variation at the coil terminals, which is the actual measured quantity, affects the flux estimate and its uncertainty. In this paper, a particle filter, implementing a sequential Monte-Carlo method based on Bayesian inference, is applied. At this aim, the main uncertainty sources are analyzed and a model of the measurement process is defined. The results of the experimental validation point out the transport system and the acquisition system as the main contributions to the uncertainty budget.

Uncertainty analysis of the magnetic field measurement by the translating coil method in axisymmetric magnets / Arpaia, Pasquale; De Vito, Luca; Kazazi, Mario. - In: METROLOGIA. - ISSN 0026-1394. - 53:6(2016). [10.1088/0026-1394/53/6/1317]

Uncertainty analysis of the magnetic field measurement by the translating coil method in axisymmetric magnets

Pasquale Arpaia
;
2016

Abstract

In the uncertainty assessment of magnetic flux measurements in axially symmetric magnets by the translating coil method, the Guide to the Uncertainty in Measurement and its supplement cannot be applied: the voltage variation at the coil terminals, which is the actual measured quantity, affects the flux estimate and its uncertainty. In this paper, a particle filter, implementing a sequential Monte-Carlo method based on Bayesian inference, is applied. At this aim, the main uncertainty sources are analyzed and a model of the measurement process is defined. The results of the experimental validation point out the transport system and the acquisition system as the main contributions to the uncertainty budget.
2016
Uncertainty analysis of the magnetic field measurement by the translating coil method in axisymmetric magnets / Arpaia, Pasquale; De Vito, Luca; Kazazi, Mario. - In: METROLOGIA. - ISSN 0026-1394. - 53:6(2016). [10.1088/0026-1394/53/6/1317]
File in questo prodotto:
File Dimensione Formato  
Metrologia Uncertainty Translating Coils 2016.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 1.56 MB
Formato Adobe PDF
1.56 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/696797
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact