This paper proposes a simplified optimum control strategy for a monoinverter dual parallel (MIDP) permanent magnet synchronous motor (PMSM).With reference to the parallel PMSM unified model, two different auxiliary conditions are investigated. The first minimizes the supplied inverter current, and the second maximizes the motor’s efficiency. Their formal expressions are derived by the introduction of three new normalized variables, linked to the load conditions. Thus, the optimumtracking considerations are general, and the parameters are independent. Simplified closed analytical forms are found for the optimum tracking, independently under steady-state and transient conditions. The selection of the best solution is then found via a parameter independent look-up table, and imposed through a closed-loop control diagram. The proposed control is compared to the present state of the art via experiments on a 1400-W MIDP PMSM test bench, showing an equivalent performance, with a lower computational burden.
Simplified Optimum Control Method for Monoinverter Dual Parallel PMSM Drive / Brando, Gianluca; Piegari, Luigi; Spina, Ivan. - In: IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS. - ISSN 0278-0046. - 65:5(2018), pp. 3763-3771. [10.1109/TIE.2017.2758751]
Simplified Optimum Control Method for Monoinverter Dual Parallel PMSM Drive
Brando, Gianluca;Piegari, Luigi;Spina, Ivan
2018
Abstract
This paper proposes a simplified optimum control strategy for a monoinverter dual parallel (MIDP) permanent magnet synchronous motor (PMSM).With reference to the parallel PMSM unified model, two different auxiliary conditions are investigated. The first minimizes the supplied inverter current, and the second maximizes the motor’s efficiency. Their formal expressions are derived by the introduction of three new normalized variables, linked to the load conditions. Thus, the optimumtracking considerations are general, and the parameters are independent. Simplified closed analytical forms are found for the optimum tracking, independently under steady-state and transient conditions. The selection of the best solution is then found via a parameter independent look-up table, and imposed through a closed-loop control diagram. The proposed control is compared to the present state of the art via experiments on a 1400-W MIDP PMSM test bench, showing an equivalent performance, with a lower computational burden.File | Dimensione | Formato | |
---|---|---|---|
2018 - Simplified Optimum Control.pdf
solo utenti autorizzati
Tipologia:
Documento in Post-print
Licenza:
Accesso privato/ristretto
Dimensione
1.09 MB
Formato
Adobe PDF
|
1.09 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.