Phenolic compounds in olive oil are considered interesting, both for their effect on human wellness and for their role in the shelf-life of olive oils. Many methods have been suggested for quantitative analysis of phenolic compounds in extra virgin olive oil, which determine results not always comparable, therefore it is necessary to have simple, inexpensive, robust and validated methods for official routine analyses. In this work, solid phase extraction (SPE) was carried out to isolate polyphenols from olive oil and the traditional colorimetric assay (Folin-Ciocalteu method) was used to quantify them. SPE/colorimetric method was validated for total polyphenols official determinations in extra virgin oils. The proposed method was robust, precise and accurate. Polyphenol recovery was excellent ≥ 95% in 100 ppm -500 ppm measuring range.
Development and validation of an analytical method for total polyphenols quantification in extra virgin olive oils / Dini, Irene; Seccia, Serenella; Senatore, Antonello; Coppola, Daniele; Morelli, Elena. - In: FOOD ANALYTICAL METHODS. - ISSN 1936-9751. - 13:(2020), pp. 457-464. [doi:10.1007/s12161-019-01657-7]
Development and validation of an analytical method for total polyphenols quantification in extra virgin olive oils
Irene Dini
;Serenella Seccia;Elena Morelli
2020
Abstract
Phenolic compounds in olive oil are considered interesting, both for their effect on human wellness and for their role in the shelf-life of olive oils. Many methods have been suggested for quantitative analysis of phenolic compounds in extra virgin olive oil, which determine results not always comparable, therefore it is necessary to have simple, inexpensive, robust and validated methods for official routine analyses. In this work, solid phase extraction (SPE) was carried out to isolate polyphenols from olive oil and the traditional colorimetric assay (Folin-Ciocalteu method) was used to quantify them. SPE/colorimetric method was validated for total polyphenols official determinations in extra virgin oils. The proposed method was robust, precise and accurate. Polyphenol recovery was excellent ≥ 95% in 100 ppm -500 ppm measuring range.File | Dimensione | Formato | |
---|---|---|---|
Dini2019_Article_DevelopmentAndValidationOfAnAn.pdf
non disponibili
Tipologia:
Documento in Post-print
Licenza:
Accesso privato/ristretto
Dimensione
1.09 MB
Formato
Adobe PDF
|
1.09 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.