Heat treatments can cause degradation in tomatoes of lycopene which has important antioxidant effects. No information about decimal reduction time (D100) of lycopene is available. D-value is the time required at a given temperature to reduce 90% of the molecule. This study for the first time determine the kinetic of lycopene thermal degradation. The content was measured at regular intervals of pasteurization using canned tomato paste to determinate D value. Microbiological analysis was carried out to verify product stability after packaging. Yeasts, molds and lactic acid bacteria were determined. The pasteurization time allowed to observe a loss of the red color. Lycopene content, after an increase at 8 min, decreased at 32 min of pasteurization. D100 value was calculated at 75 min; a diminution of 90% in lycopene content in the concentrated tomato paste was observed. Microbiological analysis confirmed the stability of products after 8 min of pasteurization.

Degradation kinetic (D100) of lycopene during the thermal treatment of concentrated tomato paste / Manzo, Nadia; Santini, Antonello; Pizzolongo, Fabiana; Aiello, Alessandra; Romano, Raffaele. - In: NATURAL PRODUCT RESEARCH. - ISSN 1478-6419. - 33:13(2019), pp. 1835-1841. [10.1080/14786419.2018.1477147]

Degradation kinetic (D100) of lycopene during the thermal treatment of concentrated tomato paste

Manzo Nadia;Santini Antonello
;
Pizzolongo Fabiana;Aiello Alessandra;Romano Raffaele
2019

Abstract

Heat treatments can cause degradation in tomatoes of lycopene which has important antioxidant effects. No information about decimal reduction time (D100) of lycopene is available. D-value is the time required at a given temperature to reduce 90% of the molecule. This study for the first time determine the kinetic of lycopene thermal degradation. The content was measured at regular intervals of pasteurization using canned tomato paste to determinate D value. Microbiological analysis was carried out to verify product stability after packaging. Yeasts, molds and lactic acid bacteria were determined. The pasteurization time allowed to observe a loss of the red color. Lycopene content, after an increase at 8 min, decreased at 32 min of pasteurization. D100 value was calculated at 75 min; a diminution of 90% in lycopene content in the concentrated tomato paste was observed. Microbiological analysis confirmed the stability of products after 8 min of pasteurization.
2019
Degradation kinetic (D100) of lycopene during the thermal treatment of concentrated tomato paste / Manzo, Nadia; Santini, Antonello; Pizzolongo, Fabiana; Aiello, Alessandra; Romano, Raffaele. - In: NATURAL PRODUCT RESEARCH. - ISSN 1478-6419. - 33:13(2019), pp. 1835-1841. [10.1080/14786419.2018.1477147]
File in questo prodotto:
File Dimensione Formato  
80 lycopene D100 2018.pdf

accesso aperto

Licenza: Dominio pubblico
Dimensione 773.34 kB
Formato Adobe PDF
773.34 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/718185
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 20
social impact